Sikalastic®-590
Sikalastic®-590 is one component polyurethane – acrylic dispersion with improved water ponding resistance, excellent UV resistance, good crack bridging capacity and great esthetics. For manual / spray application, Sikalastic®-590 can be applied as coating or a reinforced liquid applied membrane with Sika® Reemat Premium-120.
- Good behavior under limited water ponding
- UV resistant and resistant to yellowing and weathering
- Highly elastic and crack-bridging
- Non-toxic and VOC compliant water based coating
- One component - ready to use
- Excellent adhesion on porous and non-porous substrates
- Seamless waterproofing membrane
- Water vapour permeable
Usage
- For waterproofing solutions in both new construction and refurbishment projects
- For roofs with many details and complex geometry when accessibility is limited
- For cost efficient life cycle extension of failing roofs
- For reflective coating to enhance energy efficiency by reducing cooling costs (Sikalastic®-590 White)
Advantages
- Good behavior under limited water ponding
- UV resistant and resistant to yellowing and weathering
- Highly elastic and crack-bridging
- Non-toxic and VOC compliant water based coating
- One component - ready to use
- Excellent adhesion on porous and non-porous substrates
- Seamless waterproofing membrane
- Water vapour permeable
Packaging
20 kg Plastic pails.
Colour
Grey and white
Product Details
Composition
Polyurethane modified acrylic dispersion.
Shelf Life
12 months from date of production if stored properly in original, unopened and undamaged sealed packaging.
Storage Conditions
The product must be stored properly in dry conditions at temperatures between +5 °C and +30 °C.
Density
| ~1.32 kg/L (at +30 °C) | (EN ISO 2811-1) |
Solid Content
~63 % by weight
System Structure
WATERPROOFING WITHOUT REINFORCEMENT
- For UV-stable coating for extend life old roofs or as reflective coating to enhance energy efficiency.
- For detail system build up, please refer to table below :
| Coating System | Product | Consumption |
| Primer coat | Sikalastic®-590 diluted with 10 % water | ~0.3 kg/m² |
| First coat | Sikalastic®-590 | ~0.5 kg/m² |
| Second coat | Sikalastic®-590 | ~0.5 kg/m² |
WATERPROOFING WITH REINFORCEMENT (SIKA®-120 REEMAT)
- For cost efficient waterproofing solutions in new construction and refurbishment projects.
- Sika® Reemat Premium-120 is applied at areas with movements, irregular substrate or to bridge cracks, joints and seams on the substrate as well as for details.
- For detail system build up, please refer to table below :
| Coating System | Product | Consumption |
| Primer coat | Sikalastic®-590 diluted with 10 % water | ~0.3 kg/m² |
| First coat* | Sikalastic®-590 | ~0.3 kg/m² |
| Second coat | Sikalastic®-590 | ~0.5 kg/m² |
| Reinforcement membrane | Sika® Reemat Premium-120 | 1 m² |
| Third coat | Sikalastic®-590 | ~0.5 kg/m² |
| Final coat | Sikalastic®-590 | 0.3–0.5 kg/m² |
* It may not be applied, if the substrate is good and the primer has covered substrate with proper consumption and enough material.
Tensile Strength
| Free film (> 7 days) | ~1.7 N/mm² |
Adhesion in Peel
| Free film (> 7 days) | ~1.5 N/mm² |
Behaviour after Artificial Weathering
| Pass, 1000 hours, UVA-340 no cracking, no blister, no delamination, no chalking | (ASTM G154) |
Solar Reflectance
| ~80 % | Sikalastic®-590 White |
Thermal Emittance
| ~0.91 | Sikalastic®-590 White |
Solar Reflectance Index
| ~100.9 (at 12 W.m-2.K-1) | Sikalastic®-590 White |
Application
Ambient Air Temperature
+15 °C min. / +35 °C max.
Relative Air Humidity
80 % r.h. max
Substrate Temperature
+15 °C min. / +35 °C max.
Dew Point
Beware of condensation, Surface temperature during application must be at least 3 °C above dew point.
Substrate Moisture Content
< 6 % moisture content.
No rising moisture according to ASTM (Polyethilene-sheet)
No water / moisture / condensation on the substrate.
Waiting Time / Overcoating
Before applying Sikalastic®-590 on Sikalastic®-590 diluted with 10 % water as primer, allow primer to dry:
| Substrate Temperature | Relative Humidity | Minimum | Maximum |
| +20 °C | 50 % | ~2 h | * Note 1 |
| +30 °C | 50 % | ~1 h | * Note 1 |
Before applying Sikalastic®-590 on Sikalastic®-590 (without reinforced), allow 1st coat to dry:
| Substrate Temperature | Relative Humidity | Minimum | Maximum |
| +20 °C | 50 % | ~6 h | * Note 1 |
| +30 °C | 50 % | ~4 h | * Note 1 |
Before applying Sikalastic®-590 on Sikalastic®-590 (reinforced WITH Sika® Reemat Premium-120), allow material to dry:
| Substrate Temperature | Relative Humidity | Minimum | Maximum |
| +20 °C | 50 % | ~24 h | * Note 1 |
| +30 °C | 50 % | ~12 h | * Note 1 |
*Note 1 : After thorough cleaning Sikalastic®-590 can be overworked with it self at any time
Applied Product Ready for Use
| Substrate Temperature | Relative Humidity | Touch Dry | Rain Resistant | Fully Cured |
| +20 °C | 50 % | ~2 h | ~10 h | ~4 d |
| +30 °C | 50 % | ~1 h | ~6 h | ~2 d |
Note : Times are approximate and will be effected by changing ambient conditions particulary temperature and relative humidity. Low temperature and high relative humidity retard curing, while high temperature and low relative air humidity accelerate curing progression.
SUBSTRATE PREPARATION
Cementitious Substrate:
- New concrete should be cured for at least 28 days and should have a Pull off strength ≥ 1.5 N/mm².
- Cementitious or mineral based substrates must be prepared mechanically using abrasive blast cleaning or scarifying equipment to remove cement laitance and to achieve an open textured surface.
- Loose friable material and weak concrete must be completely removed and surface defects such as blowholes and voids must be fully exposed.
- Repairs to the substrate, filling of joints, blowholes/voids and surface levelling must be carried out using appropriate products from the Sikafloor®, SikaDur® and SikaGard® range of materials.
- High spots must be removed by e.g. grinding.
- Outgassing is a naturally occurring phenomenon of concrete that can produce pinholes in subsequently applied coatings. The concrete must be carefully assessed for moisture content, air entrapment, and surface finish prior to any coating work. Installing the membrane either when the concrete temperature is falling or stable can reduce outgassing. It is generally beneficial, therefore, to apply the embedment coat in the late afternoon or evening.
- Prime the substrate and always use a reinforced system.
Brick and stone:
Mortar joints must be sound and preferably flush pointed. Use localized reinforcement over joints and prime before applying Sikalastic®-590.
Slates, Tiles, etc.:
Ensure all slates/tiles are sound and securely fastened, replacing obviously broken or missing sections. Fully glazed tiles must be abraded prior to priming and subsequent treatment with Sikalastic®-590.
Bituminous Felt:
Ensure that bituminous felt is firmly adhered or mechanically fixed to the substrate. Bituminous felt should not contain any badly degraded areas. Prime and always use a totally reinforced system.
Bituminous Coatings:
Bituminous coatings should not have sticky or mobile surfaces, volatile mastic coatings, or old coal tar coatings. Prime and always use a totally reinforced system.
Metals:
Metals should be in sound condition. Abrade the exposed surfaces to reveal bright metal. Use locally reinforcement over joints and fixings.
Wooden substrates:
Timber and timber based panel roof decks are to be in good condition, firmly adhered, or mechanically fixed.
Paints/Coatings:
Ensure the existing material is sound and firmly adhered. Remove any oxidized layers and use localized reinforcement over joints.
MIXING
Prior to application, stir Sikalastic®-590 thoroughly for 1 minute in order to achieve a homogeneous mixture. Over mixing must be avoided to minimise air entrainment.
APPLICATION
Prior the application of Sikalastic®-590, the priming coat has to be used and it must have cured tack-free. The primer coat is Sikalastic®-590 diluted 10 % water and consumption is ~0.3 kg/m²
For the Waiting Time / Overcoating please refer to the PDS of the appropriate primer. Damageable areas (door frame) have to be protected with an adhesive tape.
Waterproofing WITHOUT Sika® Reemat Premium-120:
Sikalastic®-590 is applied in three coats (1 coat is for primer coat & 2 coats are Sikalastic®-590). Prior to the application of second coat the indicated waiting time in the table Waiting Time / Overcoating shall be allowed.
Waterproofing WITH Sika® Reemat Premium-120:
- Apply primer Sikalastic®-590 diluted with 10% water, consumption approximately 0.3 kg per m².
- Apply first coat* of approximately 0.3 kg per m².
- Apply second coat of approximately 0.5 kg/m² of Sikalastic®-590. Work only so far in advance that the material stays liquid.
- Roll in the Sika® Reemat Premium-120 and push into the wet liquid and ensure full saturation. Overlapping of the Sika® Reemat Premium-120 a minimum 5 cm and ensure overlaps are sufficiently wet to bond. The roller may require only a little extra material to keep wetted but no further significant material needs to be added at this stage. The surface of the reinforcement should look wet and fully sealed. Then apply approximately 0.5 kg per m² of Sikalastic®-590 with wet on wet system.
- Before applying the final coat, check for upstanding reemat fibres. These fibres have to be eliminated by using sandpaper. Make sure that all upstanding fibres are abraded.
- After the coat is dry enough to walk on, Final coat of approximately 0.3–0.5 kg per m² of Sikalastic®-590.
Note : * It may not be applied, if the substrate is good and the primer has covered substrate with proper consumption and enough material.
TOOLS
Drill and paddle:
Sikalastic®-590 should be mixed for one minute using a drill and paddle.
Solvent resistant short-piled lamb skin roller:
Used in the application of Sikalastic®-590 to ensure a consistent thickness of the seamless SikaRoof® systems.
Thick hair brush:
For application of Sikalastic®-590 to all details and penetrations.
Jet Washer:
If dust, vegetation, moss / algae or other contaminants are present on the existing roof, a power washer is required to clean the substrate prior to the application of SikaRoof® Systems. Existing chippings should be removed by hand or scabbling prior to power washing.
Airless spray equipment:
Used only for the roof coating systems. Two spray applied layers is the minimum requirement. The pump should have the following parameter:
-min. pressure : 220 bar
-min. output : 5.1 l/min
-min. Ø nozzle : 0.83 mm (0.033 inch)
For example : Wagner Heavycoat HC 940 E SSP Spray pack
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened/cured material can only be removed mechanically.
FAQ
Before applying a cool roof coating, inspect the roof surface for damage, loose material, cracks and contaminants. The substrate must be clean, dry and free from oil, grease and dust. For Sikalastic®-590, ensure the roof has adequate slope to avoid water ponding.
For SikaCoat-500 Super & SikaCoat-555, check for existing cracks requiring repair before applying reflective coating roof systems. Repair damaged areas, remove loose material and prime if required. Sika Malaysia recommends assessing the roof's structural condition and confirming compatibility before cool coat application. Proper preparation ensures lasting roof waterproofing performance.
Yes, cool roof systems are suitable for commercial and industrial buildings. Sika Malaysia provides roof solutions for flat and sloping fully exposed roof structures in new construction and roof restoration projects. The energy-saving benefits are valuable for large commercial buildings with significant cooling demands.
Sikalastic®-590 suits roofs with complex geometry and limited accessibility, common in industrial settings, providing reflective coating roof performance to reduce cooling costs. SikaCoat-500 Super & SikaCoat-555 offer tough, durable reinforced protective roof coating suitable for exposed roofs. These cool roof systems help reduce operational costs and improve building sustainability.
Yes, cool roof coating systems are well suited to roof restoration projects. Sikalastic®-590 is designed for roof waterproofing solutions in new construction and refurbishment, extending the life cycle of failing roofs. It suits roofs with complex geometry where accessibility is limited.
SikaCoat-500 Super & SikaCoat-555 are ideal for roof restoration projects on concrete roofs, metal and fibre cement board, providing roof waterproofing and solar reflectivity. Using a cool roof coating during refurbishment adds energy efficiency alongside waterproofing. Sika Malaysia recommends assessing existing roof condition before applying reflective coating roof systems.
Applying a cool roof coating to an existing roof involves surface preparation, priming if required, and application by brush, roller or spray. For Sikalastic®-590, clean the roof surface and apply the roof coating to achieve the recommended dry film thickness.
SikaCoat-333 is self-priming, simplifying cool coat sika application on concrete, metal and other substrates. SikaCoat-500 Super & SikaCoat-555 can be applied directly by brush, roller or spray. Ensure the roof is dry and free from contaminants before applying heat reflective paint for roof. Apply evenly and allow adequate curing between coats, following Sika Malaysia application instructions.