Sikafloor® MultiDur EB-31
Sikafloor® MultiDur EB-31 is a slip resistant, coloured epoxy covering with high chemical and mechanical resistance for flooring applications
- High chemical resistance
- High mechanical resistance
- Liquid proof
- Slip resistant
System Structure
1
Wearing coat /Top coat
Usage
- Suitable for concrete and screed surfaces in areas with high chemical and mechanical exposures.
- Production and processing areas in food industry and automotive industry
Advantages
- High chemical resistance
- High mechanical resistance
- Liquid proof
- Slip resistant
Packaging
Please refer to the individual Product Data Sheets
Colour
Available in various colour shades.
Appearance
Slip resistant, gloss finish
System Details
APPROVALS / STANDARDS
- Slip resistance certificate according to DIN 51130, class R12 V8, Report No.020108-13-19, Roxeler Institute, October 2013, Germany
System Structure
Sikafloor® MultiDur EB-31 system (~ 2–3 mm)
1. Primer | Sikafloor®-161 HC |
2. Wearing coat & broadcast | Sikafloor®-381 & broadcast with silicon carbide 0.5–1.0 mm or quartz sand 0.4–0.7 mm |
3. Top coat | Sikafloor®-381 + 5 % by weight Thinner C |
Composition
Epoxy
Nominal Thickness
~2.0–3.0 mm
Shelf Life
Please refer to the individual Product Data Sheets
Storage Conditions
Please refer to the individual Product Data Sheets
Chemical Resistance
Refer to the chemical resistance of Sikafloor®-381
Temperature Resistance
Exposure* | Dry heat |
Permanent | +50 °C |
Short-term max. 7 d | +80 °C |
Short-term max. 12 h | +100 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional (i.e. during steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Skid / Slip Resistance
R12 V 8 | (DIN 51130) |
Application
Product Temperature
Please refer to the individual Product Data Sheet
Ambient Air Temperature
+10 °C min. / +30 °C max.
Relative Air Humidity
80 % r.h. max.
Dew Point
Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.
Substrate Temperature
+10 °C min. / +30 °C max.
Substrate Moisture Content
When performing application work with Sikafloor® MultiDur EB-31, the substrate moisture content must not exceed 4 % pbw measured by Tramex.
Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Waiting Time / Overcoating
Before applying Sikafloor®-381 on Sikafloor®-161 HC allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 4 days |
+20 °C | 12 hours | 2 days |
+30 °C | 8 hours | 1 day |
Before applying Sikafloor®-381 on Sikafloor®-381 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 48 hours |
+20 °C | 18 hours | 24 hours |
+30 °C | 6 hours | 12 hours |
Applied Product Ready for Use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~ 24 hours | ~ 3 days | ~ 10 days |
+20 °C | ~ 18 hours | ~ 2 days | ~ 7 days |
+30 °C | ~ 12 hours | ~ 1 day | ~ 5 days |
Consumption
Sikafloor® MultiDur EB-31 system (~ 2–3 mm)
Coating System | Product | Consumption |
Primer | Sikafloor®-161 HC | ~ 0.3–0.5 kg/m² |
Wearing coat | Sikafloor®-381 (unfilled) | ~ 1.6 kg/m² |
Broadcast in excess | Silicon Carbide 0.5–1.0 mm or quartz sand 0.4–0.7 mm | ~ 4–6 kg/m² |
Top coat | Sikafloor®-381 + 5 % by weight Thinner C | ~0.75–0.85 kg/m² |
CLEANING
Please refer to the Method Statement Sikafloor®‐ Cleaning Regime